Decompression comparison of helium and hydrogen in rats
by E.C. Parker, R.S. Lillo, W.R. Porter
Abstract:
The hypothesis that there are differences in decompression risk between He and H2 was examined in 1,607 unanesthetized male albino rats subjected to dives on 2% O2-balance He or 2% O2-balance H2 (depths < or = 50 ATA, bottom times < or = 60 min). The animals were decompressed to 10.8 ATA with profiles varying from rapid to slow, with up to four decompression stops of up to 60 min each. Maximum likelihood analysis was used to estimate the relative decompression risk on a per unit pressure basis (termed ‘potency’) and the rate of gas uptake and elimination, both factors affecting the decompression sickness risk, from a specific dive profile. H2 potency for causing decompression sickness was found to be up to 35% greater than that for He. Uptake rates were unresolvable between the two gases with the time constant (TC) estimated at approximately 2-3 min, leading to saturation in both cases in < 15 min. Washout of both gases was significantly slower than uptake, with He washout (TC approximately 1.5-3 h) substantially slower than H2 washout (TC approximately 0.5 h). It is unknown whether the decompression advantage of the faster washout of H2 or the disadvantage of its increased potency, observed in the rat, would be important for human diving.
Read more:
https://doi.org/10.1152/jappl.1997.82.3.892
Related Articles:
Introduction: Hydrogen (H2) has been reported to be effective in the treatment of oxidative injury, which plays an important role in the process of decompression sickness (DCS). This study was designed to test whether H2-rich saline (saline saturated with molecular…
Exposure to high oxygen concentrations leads to acute lung injury, including lung tissue and alveolar edema formation, congestion, intra-alveolar hemorrhage, as well as endothelial and epithelial cell apoptosis or necrosis. Several studies have reported that molecular hydrogen is an efficient…
Biochemical decompression, a novel approach for decreasing decompression sickness (DCS) risk by increasing the tissue washout rate of the inert gas, was tested in pigs during simulated H2 dives. Since there is only limited physiological data on the use of…
During the 7.1-MPa hydrogen-helium-oxygen record human dive, we tested the hypothesis that the increased ambient pressure would alter the maximal muscle performance, specifically that breathing dense gas would lead to fatigue of the respiratory muscle. A group of hand muscles…
Electrocardiogram (ECG) analysis was performed in three human divers during a 71 atm (7,200 kPa) saturation dive (COMEX HYDRA 10 experiment). The inhaled gas mixture was slightly hyperoxic; its composition was basically helium and oxygen. Hydrogen was introduced during compression…






0 Comments